Steel Mill Products
LEVER ACTION HOLDERS

| ALL HOLDERS ARE SHIPPED WITH A RUBBER GROMMET INSTALLED | |||
| # 1 LEVER ACTION HOLDER for .405” ( 1/8” pipe) | |||
| PART # | DESCRIPTION | ||
| .405” O.D. tube or 1/8” Pipe | HOLDER WITH SHIELD | ||
| LA1405 | #1 Lever Action Holder (no valve) w/ .405 Grommet | LA1405-S | with Hand Shield |
| PL1/8-6 | Rubber Grommet for 405” pipe for LA 1 Holder | ||
| LA1405F | #1 Lever Action Holder w/ 1/2” Thermal Shutoff | LA1405FS | with Hand Shield |
| LA1405FB | #1 Lever Action Holder w/ Ball Valve & Thermal Shutoff | LA1405FBS | with Hand Shield |
| *LA1405FV | #1 Lever Action Holder w/ V-05 Valve & Thermal Shutoff | LA1405FVS | with Hand Shield |
|
.540” O.D. tube or 1/4” Pipe
|
HOLDER WITH SHIELD | ||
| LA1540 | #1 Lever Action Holder (no valve) w/ .540” Grommet | LA1540-S | with Hand Shield |
| PL 10-6 | Rubber Grommet for .540” (1/4” pipe) for LA 1 Holder | ||
| LA154F | #1 Lever Action Holder w/ 1/2” Thermal Shutoff | LA154F-S | with Hand Shield |
| LA1540FB | #1 Lever Action Holder w/ Ball Valve & Thermal Shutoff | LA1540FBS | with Hand Shield |
| *LA1540FV | #1 Lever Action Holder w/ V-05* Valve & Thermal Shutoff | LA1540FVS | with Hand Shield |
|
# 2 LEVER ACTION HOLDER for .540” .625” and .675” O.D. pipe
|
|||
| .540” O.D. tube or 1/4” Pipe w/ CGA “B” for 3/8” hose | HOLDER WITH SHIELD | ||
| LA254 | # 2 Lever Action Holder (no valve ) w/ .540” Grommet | LA254-S | with Hand Shield |
| LA254I | LA 2 Rubber Grommet for .540” (1/4” pipe) | ||
| LA254FB-B | # 2 LA Holder w/ Ball Valve & 1/2” Thermal Shutoff | LA254FBS-B | with Hand Shield |
| *LA254FV-B | # 2 LA Holder w/ V-05* Valve & 1/2” Thermal Shutoff | LA254FVS-B | with Hand Shield |
| .540” O.D. tube 1/4” Pipe with/ CGA “C” for 1/2” hose | HOLDER WITH SHIELD | ||
| LA254FB-C | # 2 LA Holder w/ Ball Valve & 1/2” Thermal Shutoff | LA254FBS-C | with Hand Shield |
| *LA254FV-C | # 2 LA Holder w/ V-05* Valve & 1/2” Thermal Shutoff | LA254FVS-C | with Hand Shield |
| .675” and .625” O.D. tube w/ CGA “B” for 3/8” hose | HOLDER WITH SHIELD | ||
| LA2675 | # 2 Lever Action Holder (no valve ) | LA2675-S | With Hand Shield |
| LA2675I | LA 2 Rubber Grommet for .625” and .675” O.D. | ||
| LA267FB-B | # 2 LA Holder w/ Ball Valve & 1/2” Thermal Shutoff | LA267FBS-B | with Hand Shield |
| *LA267FV-B | # 2 LA Holder w/ V-05* Valve & 1/2” Thermal Shutoff | LA267FVS-B | with Hand Shield |
| .675” and .625” O.D. tube w/ CGA “C” for 1/2” hose | HOLDER WITH SHIELD | ||
| LA267FB-C | # 2 LA Holder w/ Ball Valve & 1/2” Thermal Shutoff | LA267FBS-C | with Hand Shield |
| *LA267FV-C | # 2 LA Holder w/ V-05* Valve & 1/2” Thermal Shutoff | LA267FVS-C | with Hand Shield |
| # 3 LEVER ACTION HOLDER for .840”, .922” or 1.050” O.D. pipe | |||
| PART # | DESCRIPTION | ||
| .840” O.D. tube or 1/2” pipe | HOLDER WITH SHIELD | ||
| LA384 | # 3 Lever Action Holder (no valve) | LA384S | with Hand Shield |
| LA3840I | LA 3 Rubber Grommet for .840” O.D. tube or 1/2” pipe | ||
| LA384F | # 3 LA Holder 3/4" NPT Thermal Shutoff (no valve) | LA384FS | with Hand Shield |
| LA384FB | # 3 LA Holder w/ Ball Valve & ¾"T hermal Shutoff | LA384FBS | with Hand Shield |
| LA384FB-C | Same as LA384FB with CGA “C” Fitting | LA384FBS-C | with Hand Shield |
| .922” O.D. tube | HOLDER WITH SHIELD | ||
| LA392 | # 3 Lever Action Holder (no valve ) | LA392S | with Hand Shield |
| LA3922I | LA 3 Rubber Grommet for .922” O.D. tube | ||
| LA3922F | # 3 LA Holder 3/4" NPT Thermal Shutoff (no valve) | LA392FS | with Hand Shield |
| LA3922FB | # 3 LA Holder w/ Ball Valve & ¾"Thermal Shutoff | LA392FBS | with Hand Shield |
| LA3922FB-C | Same as LA392FB with CGA “C” Fitting | LA392FBS-C | with Hand Shield |
| 1.05” O.D. tube or 3/4” pipe | HOLDER WITH SHIELD | ||
| LA3105 | # 3 Lever Action Holder (no valve ) | LA3105S | with Hand Shield |
| LA3105I | LA 3 Rubber Grommet for 1.05” O.D. tube or 3/4” pipe | ||
| LA3105F | # 3 LA Holder 3/4" NPT Thermal Shutoff (no valve) | LA3105FS | with Hand Shield |
| LA3105FB | # 3 LA Holder w/ Ball Valve & 3/4"Thermal Shutoff | LA3105FBS | with Hand Shield |
| LA3105FB-C | Same as LA3105FB with CGA “C” Fitting | LA3105FBS-C | with Hand Shield |
| NO SHIELD AVAILABLE FOR LA4 OR LA5 HOLDERS | |||
| # 4 LEVER ACTION HOLDER for 1.250” tube or 1.315” O.D. tube or 1” pipe | |||
| LA 41315 | # 4 Lever Action Holder (no valve ) | ||
| LA41315I | LA 4 Rubber Grommet for 1.25” and 1.315” O.D. tube or 1”pipe | ||
| LA 41315F4 | # 4 LA Holder w/ 1 1/4” Thermal Shutoff | ||
| LA 41315FB4 | # 4 LA Holder w/ Ball Valve & 1 1/4” Thermal Shutoff | ||
| 1.315” Rubber Insert works for both 1.250 and 1.315 inch O.D. | |||
| # 5 LEVER ACTION HOLDER for 1.66” O.D. tube or 1 1/4” pipe | |||
| LA 5166 | # 5 Lever Action Holder (no valve ) | ||
| LA5166I | LA 5 Rubber Grommet for 1.66” O.D. tube or 1 1/4” pipe | ||
| LA5166F | # 5 LA Holder w/ 1 1/4” Thermal Shutoff | ||
| LA5166FB | # 5 LA Holder w/ Ball Valve & 1 1/4” Thermal Shutoff | ||
For the LA 2 Holder the LA2675I Insert fits both .625” and .675” diameter tube
FOR ALL HOLDERS FOR BURNING BARS AND LANCE PIPE LARGER THAN .540” OXYLANCE RECOMMENDS THAT 1/2” HOSE BE USED WHICH REQUIRES A CGA “C” FITTING
*V-O5 VALVE NOT RECOMMENDED FOR PRESSURES OVER 200 PSI